DC 5,000E, Portable Electric Dust Collector One (1) Month Minimum Rental Period
This 5,000cfm dust collector was designed by SAFE Systems to provide the contractor a unit for tight spaces. The original design was developed for use at the Kennedy Space Center. Caster mounted, with fork lift pockets and certified crane lifting eyes, the compact unit can easily be positioned in an optimum location. The compact size allows it to be pushed through halls and doorways and transported on cargo elevators, reaching positions inside structures that otherwise would require long duct lengths. One (1) 18” duct connection makes connecting vent hose quick. A large, container-style door makes filter and dust drawer access easy. Six (6) cartridge filters collect the dust particles and are cleaned by a reverse pulse jet of compressed air, one row of three (3) filters, at a time. The dust particles then fall into the dust drawer below that can be emptied by pulling it out or through the optional vacuum port on the back. Belts and drives are eliminated by the direct-drive 15 HP motor. The NEMA 4 control box is dust and water tight to protect the electrical controls from contaminants and moisture. The unit comes with 25’ of the properly sized SO cord to allow electrical connection at the job site. One large, easy to open and close “Container Style” door gives quick access to the filters and dust drawer. Unit may be used with the HEPA-5000 After-filter System. Some on-site assembly will be required if the contractor needs to take the HEPA-5000 and DC 5,000-E combination through standard 3' x 7' doorways. Dust Collector Spare Parts
Specifications: Manufacturer: SAFE Systems, Inc. Length 5’-3” Width 2’-10” Height 7’-1-3/4" Weight 1,750 lbs. (completely empty of dust) Horsepower 15 Voltage 460 VAC, 3 phase Full load Amps 18 Features: Designed for use in areas with limited accessibility Fits through man door with 3’ x 7’ opening. Small physical size and weight allows the unit to be transported in a cargo elevator. Swivel casters with brakes mounted on the base for easy movement. Forklift pockets. Certified lifting eyes for handling by overhead crane. Dust collector housing is rated for 15” W.C. Fan rated for 5,000 CFM @12” W.C. Six (6) cartridge filters, part #1000 0300 3.2 to 1 air-to-cloth ratio. Differential pressure gauge to indicate filter condition during operation. One (1) dust inlet, 18” diameter. Automatic compressed air reverse pulse cleaning system for filters. ¾” air connection with filter and regulator for the customer supplied air source. Air requirements: 30 CFM @ 90 to 100 PSIG Fan is direct driven by a 15 HP, 460-volt, 3-phase electric motor. 120 volt AC, 1 phase controls for pulse cleaning system. Dust drops into removable dust drawer or can vacuumed out through vacuum port. NEMA 4, 460 VAC electrical control box is rated for outside use in wet and dusty conditions. 25’ of properly sized SO cord for electrical hook-up.
Optional Equipment: Model HEPA-5000 filter module is available for the fan discharge air (the fan discharge transition adds 18” to operating height) Notes: 1. Not intended to be shipped or moved with any dust in the collector. 2. Not intended to be laid down horizontally for shipment. 3. Recommend emptying dust every 2 to 4 hours depending on collection rate. 4. Recommend connection to power be made by a qualified electrician 5. Have electrician verify correct fan rotation after connection 6. Recommend all new filters be coated with precoat dust prior to putting into service. 5. If operating this equipment using a generator, check with the generator provider to ensure proper sizing.We recommend at least a 30 KW generator for this piece of equipment. 6. Using the HEPA module requires the use of a fan discharge transition which adds 18" to operating height.The transition can be installed on site to enable the unit to still fit through doorways and hallways.